Value
SCPI Commands
CALCulate<Window>:LIMit:MACCuracy:FERRor:RPEak:VALue
- class ValueCls[source]
Value commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(window=Window.Default) float [source]
# SCPI: CALCulate<n>:LIMit:MACCuracy:FERRor:RPEak:VALue value: float = driver.applications.k70Vsa.calculate.limit.maccuracy.freqError.rpeak.value.get(window = repcap.Window.Default)
This command defines the value for the current, peak or mean frequency error (peak or RMS) limit. Note that the limits for the current and the peak value are always kept identical. This command is available for FSK modulation only.
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)
- return
limit_value: the value x (x0) defines the interval [-x; x] Range: 0.0 to 100, Unit: Hz
- set(limit_value: float, window=Window.Default) None [source]
# SCPI: CALCulate<n>:LIMit:MACCuracy:FERRor:RPEak:VALue driver.applications.k70Vsa.calculate.limit.maccuracy.freqError.rpeak.value.set(limit_value = 1.0, window = repcap.Window.Default)
This command defines the value for the current, peak or mean frequency error (peak or RMS) limit. Note that the limits for the current and the peak value are always kept identical. This command is available for FSK modulation only.
- param limit_value
the value x (x0) defines the interval [-x; x] Range: 0.0 to 100, Unit: Hz
- param window
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)