SENSe:LIST:RANGe<RangePy>:FREQuency:STARt
- class StartCls[source]
Start commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(rangePy=RangePy.Default) float [source]
# SCPI: [SENSe]:LIST:RANGe<ri>[:FREQuency]:STARt value: float = driver.sense.listPy.range.frequency.start.get(rangePy = repcap.RangePy.Default)
This command queries the start frequency offset of a half decade.
- param rangePy
optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Range’)
- return
frequency: numeric value Unit: Hz
- set(frequency: float, rangePy=RangePy.Default) None [source]
# SCPI: [SENSe]:LIST:RANGe<ri>[:FREQuency]:STARt driver.sense.listPy.range.frequency.start.set(frequency = 1.0, rangePy = repcap.RangePy.Default)
This command queries the start frequency offset of a half decade.
- param frequency
numeric value Unit: Hz
- param rangePy
optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Range’)