Source code for RsFswp.Implementations.Applications.K70_Vsa.Trigger.Sequence.IfPower.Holdoff

from .......Internal.Core import Core
from .......Internal.CommandsGroup import CommandsGroup
from .......Internal import Conversions
from ....... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class HoldoffCls: """Holdoff commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("holdoff", core, parent)
[docs] def set(self, period: float, triggerPort=repcap.TriggerPort.Default) -> None: """SCPI: TRIGger<tp>[:SEQuence]:IFPower:HOLDoff \n Snippet: driver.applications.k70Vsa.trigger.sequence.ifPower.holdoff.set(period = 1.0, triggerPort = repcap.TriggerPort.Default) \n This command defines the holding time before the next trigger event. Note that this command can be used for any trigger source, not just IF Power (despite the legacy keyword) . Note: If you perform gated measurements in combination with the IF Power trigger, the R&S FSWP ignores the holding time for frequency sweep, FFT sweep, zero span and I/Q data measurements. \n :param period: Range: 0 s to 10 s, Unit: S :param triggerPort: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger') """ param = Conversions.decimal_value_to_str(period) triggerPort_cmd_val = self._cmd_group.get_repcap_cmd_value(triggerPort, repcap.TriggerPort) self._core.io.write(f'TRIGger{triggerPort_cmd_val}:SEQuence:IFPower:HOLDoff {param}')
[docs] def get(self, triggerPort=repcap.TriggerPort.Default) -> float: """SCPI: TRIGger<tp>[:SEQuence]:IFPower:HOLDoff \n Snippet: value: float = driver.applications.k70Vsa.trigger.sequence.ifPower.holdoff.get(triggerPort = repcap.TriggerPort.Default) \n This command defines the holding time before the next trigger event. Note that this command can be used for any trigger source, not just IF Power (despite the legacy keyword) . Note: If you perform gated measurements in combination with the IF Power trigger, the R&S FSWP ignores the holding time for frequency sweep, FFT sweep, zero span and I/Q data measurements. \n :param triggerPort: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Trigger') :return: period: Range: 0 s to 10 s, Unit: S""" triggerPort_cmd_val = self._cmd_group.get_repcap_cmd_value(triggerPort, repcap.TriggerPort) response = self._core.io.query_str(f'TRIGger{triggerPort_cmd_val}:SEQuence:IFPower:HOLDoff?') return Conversions.str_to_float(response)