SymbolRate

SCPI Commands

TRACe:IQ:SRATe
class SymbolRateCls[source]

SymbolRate commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get() int[source]
# SCPI: TRACe:IQ:SRATe
value: int = driver.applications.iqAnalyzer.trace.iq.symbolRate.get()

This command sets the final user sample rate for the acquired I/Q data. Thus, the user sample rate can be modified without affecting the actual data capturing settings on the R&S FSWP. Note: The smaller the user sample rate, the smaller the usable I/Q bandwidth, see ‘Sample rate and maximum usable I/Q bandwidth for RF input’.

return

count: No help available

set(count: int) None[source]
# SCPI: TRACe:IQ:SRATe
driver.applications.iqAnalyzer.trace.iq.symbolRate.set(count = 1)

This command sets the final user sample rate for the acquired I/Q data. Thus, the user sample rate can be modified without affecting the actual data capturing settings on the R&S FSWP. Note: The smaller the user sample rate, the smaller the usable I/Q bandwidth, see ‘Sample rate and maximum usable I/Q bandwidth for RF input’.

param count

The valid sample rates are described in ‘Sample rate and maximum usable I/Q bandwidth for RF input’. Unit: HZ